5.3 Description of Function Codes 5.3.9 d codes (Applied functions 2)
Master side inverter
Forward rotation (FWD)
When FWD-CM shorted
Reverse rotation (REV)
When REV-CM shorted
Connection
in UVW
phase order
Connection
not in UVW
phase
order
Connection
in UVW
phase
order
Connection
not in UVW
phase
order
When XA-A phase,
XB-B phase connected
I/O check:
“4_15” polarity
-: Reverse
rotation
(REV)
+: Forward
rotation
(FWD)
+: Forward
rotation
(FWD)
-: Reverse
rotation
(REV)
When XA-B phase,
XB-A phase connected
I/O check:
“4_15” polarity
+: Forward
rotation
(FWD)
-: Reverse
rotation
(REV)
-: Reverse
rotation
(REV)
+: Forward
rotation
(FWD)
CW: Clockwise (right rotation) as viewed from shaft side
CCW: Counterclockwise (left rotation) as viewed from shaft side
shows the rotation direction for the configuration example in Fig. 5.3-45.
Follower side inverter
Forward rotation (FWD)
When FWD to CM shorted
Reverse rotation (REV)
When REV-CM shorted
Connection
in UVW
phase order
Connection
not in UVW
phase
order
Connection
in UVW
phase
order
Connection
not in UVW
phase
order
When YA-A phase, YB-
B phase connected
I/O check:
“4_17” polarity
+: Forward
rotation
(FWD)
-: Reverse
rotation
(REV)
-: Reverse
rotation
(REV)
+: Forward
rotation
(FWD)
When YA-B phase, YB-
A phase connected
I/O check:
“4_17” polarity
-: Reverse
rotation
(REV)
+: Forward
rotation
(FWD)
+: Forward
rotation
(FWD)
-: Reverse
rotation
(REV)
CW: Clockwise (right rotation) as viewed from shaft side
CCW: Counterclockwise (left rotation) as viewed from shaft side
shows the rotation direction for the configuration example in Fig. 5.3-45.