5.3 Description of Function Codes 5.3.9 d codes (Applied functions 2)
5-335
FUNCTION CODES
Chap 5
FUNCTION
CODES
F Codes
E Codes
C Codes
P Codes
H Codes
A Codes
b Codes
r Codes
J Codes
d Codes
U Codes
y Codes
K Codes
Unavailable function codes
During master-follower operation, the following functions are not available.
F16
Frequency Limiter (Low)
C01 to
C04
Jump frequency
Selecting “Vector control for induction motor with speed sensor” (F42 = 6) disables the settings of the following
functions during master-follower operation, as well as making the above functions unavailable.
F07, F08
Acceleration Time
1/Deceleration Time 1
E10, E11
Acceleration Time
2/Deceleration Time 2
E13, E14
Acceleration Time
3/Deceleration Time 3
E15, E16
Acceleration Time
4/Deceleration Time 4
F24
Starting frequency (Holding
time)
F39
Stop frequency (Holding
time)
During master-follower operation, the following control should be disabled (H18 = 0, J01 = 0).
H18
Torque control
J01
PID control
To perform master-follower operation, be sure to select a control mode with speed sensor (F42 = 3, 4 or 6) and
configure the function codes given in this section. Set other function codes based on the following function code
setting procedure.