5.3 Description of Function Codes 5.3.9 d codes (Applied functions 2)
5-354
Function
code
Name
Data setting range
Unit
Factory
default
Change
during
operation
d251
Positioning data 4 - 4
lower order digits
0 to 9999
U
0
Y
d252
Positioning data 5 - 4
higher order digits
-9999 to +9999
U
0
Y
d253
Positioning data 5 - 4
lower order digits
0 to 9999
U
0
Y
d254
Positioning data 6 - 4
higher order digits
-9999 to +9999
U
0
Y
d255
Positioning data 6 - 4
lower order digits
0 to 9999
U
0
Y
d256
Positioning data 7 - 4
higher order digits
-9999 to +9999
U
0
Y
d257
Positioning data 7 - 4
lower order digits
0 to 9999
U
0
Y
d258
Positioning data 8 - 4
higher order digits
-9999 to +9999
U
0
Y
d259
Positioning data 8 - 4
lower order digits
0 to 9999
U
0
Y
d276
Positioning data
(infinite direction)
0: Disable
1: Forward rotation direction
2: Reverse rotation direction
-
0
Y
d277
Positioning data
communication
command selection
0: Disable positioning data communication command
1: Disable positioning data communication command
-
0
Y
d280
Operation during
emergency stop
0: Servo lock after deceleration stop
1: Er6 alarm after deceleration stop
-
0
Y
d296
Command current
position monitor - 4
higher order digits
-9999 to +9999
U
-
-
d297
Command current
position monitor - 4
lower order digits
0 to 9999
U
-
-
d298
Feedback current
position monitor - 4
higher order digits
-9999 to +9999
U
-
-
d299
Feedback current
position monitor - 4
lower order digits
0 to 9999
U
-
-
Unit U indicates the user value.