5.3 Description of Function Codes 5.3.9 d codes (Applied functions 2)
5-353
FUNCTION CODES
Chap 5
FUNCTION
CODES
F Codes
E Codes
C Codes
P Codes
H Codes
A Codes
b Codes
r Codes
J Codes
d Codes
U Codes
y Codes
K Codes
Function
code
Name
Data setting range
Unit
Factory
default
Change
during
operation
d223
Deviation detection
overflow value - 4 higher
order digits
0 to 9999 * Disable when 0 for both d223, d224
U
0
Y
d224
Deviation detection
overflow value - 4 lower
order digits
0 to 9999 * Disable when 0 for both d223, d224
U
0
Y
d225
+ software OT detection
position - 4 higher order
digits
-9999 to +9999
U
+9999
N
d226
+ software OT detection
position - 4 lower order
digits
0 to 9999
U
9999
N
d227
- software OT detection
position - 4 higher order
digits
-9999 to +9999
U
-9999
N
d228
- software OT detection
position - 4 lower order
digits
0 to 9999
U
9999
N
d229
Pass point detection
position 1 - 4 higher
order digits
-9999 to +9999
U
0
Y
d230
Pass point detection
position 1 - 4 lower order
digits
0 to 9999
U
0
Y
d231
Pass point detection
position 2 - 4 higher
order digits
-9999 to +9999
U
0
Y
d232
Pass point detection
position 2 - 4 lower order
digits
0 to 9999
U
0
Y
d237
Positioning data type
(INC/ABS switching)
0: Handle positioning data as absolute position (ABS)
1: Handle positioning data as travel (INC)
-
0
Y
d238
Positioning data
selection signal
agreement timer
0.000 to 0.100
s
0.000
Y
d239
In-position range
0 to 9999
U
1
Y
d240
Preset position - 4
higher order digits
-9999 to +9999
U
0
Y
d241
Preset position - 4 lower
order digits
0 to 9999
U
0
Y
d242
Homing shift - 4 higher
order digits
0 to 9999
U
0
Y
d243
Homing shift - 4 lower
order digits
0 to 9999
U
0
Y
d244
Positioning data 1 - 4
higher order digits
-9999 to +9999
U
0
Y
d245
Positioning data 1 - 4
lower order digits
0 to 9999
U
0
Y
d246
Positioning data 2 - 4
higher order digits
-9999 to +9999
U
0
Y
d247
Positioning data 2 - 4
lower order digits
0 to 9999
U
0
Y
d248
Positioning data 3 - 4
higher order digits
-9999 to +9999
U
0
Y
d249
Positioning data 3 - 4
lower order digits
0 to 9999
U
0
Y
d250
Positioning data 4 - 4
higher order digits
-9999 to +9999
U
0
Y

Table of Contents