5.3 Description of Function Codes 5.3.9 d codes (Applied functions 2)
5-359
FUNCTION CODES
Chap 5
FUNCTION
CODES
F Codes
E Codes
C Codes
P Codes
H Codes
A Codes
b Codes
r Codes
J Codes
d Codes
U Codes
y Codes
K Codes
Positioning data
Up to 8 points of positioning data can be set in user value units. These points are selected with a combination of
digital input positioning data selection signals “POS-SEL1”, “POS-SEL2", and “POS-SEL4. To prevent chattering,
the selection will change if the positioning data selection signal does not change until the d238: positioning data
selection signal agreement timer time elapses. Positioning data can be changed while performing position control.
To reflect the changed position, turn ON positioning data change command “POS-SET”.
If positioning data is changed while the motor is stopped, there will be no need to turn ON positioning data change
command “POS-SET”.
“POS-SEL4”
“POS-SEL2”
“POS-SEL1”
Function code
LED
Range (user value unit)
OFF
OFF
OFF
d244, d245
Positioning data 1
±99,999,999
OFF
OFF
ON
d246, d247
Positioning data 2
±99,999,999
OFF
ON
OFF
d248, d249
Positioning data 3
±99,999,999
OFF
ON
ON
d250, d251
Positioning data 4
±99,999,999
ON
OFF
OFF
d252, d253
Positioning data 5
±99,999,999
ON
OFF
ON
d254, d255
Positioning data 6
±99,999,999
ON
ON
OFF
d256, d257
Positioning data 7
±99,999,999
ON
ON
ON
d258, d259
Positioning data 8
±99,999,999
Function
code
Name
Data setting range
Unit
Factory
default
Change
during
operation
E01 to E09
E98
E99
Terminal [X1] to [X9]
(Function selection)
Terminal [FWD]
(Function selection)
Terminal [REV]
(Function selection)
135(1135):
Travel/absolute position switching
“INC/ABS”
144(1144):
Positioning data change command “POS-
SET”
145(1145):
Positioning data selection 1 “POS-SEL1”
146(1146):
Positioning data selection 2 “POS-SEL2”
147(1147):
Positioning data selection 4 “POS-SEL4”
-
-
N
d237
Positioning data type
(INC/ABS switching)
0: Handle positioning data as absolute
position (ABS)
1: Handle positioning data as travel (INC)
-
0
Y
d238
Positioning data selection
agreement timer
0.000 to 0.100
s
0.000
Y
d277
Positioning data communication
command selection
0: Disable positioning data
communication command (S20, S21)
1: Enable positioning data
communication command (S20, S21)
-
0
Y
S20, S21
Positioning data communication
(high order, low order)
±99,999,999
U
0
Y