2.2 Wiring
2-20
Table 2.2-4 Wire size (for DC reactor connection, for braking resistor connection, and for inverter grounding)
(cont.)
HHD specification: High, Heavy Duty applications
HND specification: High, Normal Duty applications
Power
system
Standard
applicable
motor (kW)
Inverter type
Recommended wire size (mm
2
)
For DC reactor connection
[P1, P(+)]
For braking resistor connection [P(+), DB] (Note 2)
For inverter
grounding
[*G]
HHD specification
HND specification
HHD specification
HND specification
Permissible
temperature (Note 1)
Current
value
(A)
Permissible
temperature (Note 1)
Current
value
(A)
Permissible
temperature (Note 1)
Current
value
(A)
Permissible
temperature (Note
1)
60 °C
75 °C
90 °C
60 °C
75 °C
90 °C
60 °C
75 °C
90 °C
60 °C
75 °C
90 °C
Three-phase
200 V
0.4
FRN0003G2S-2G
-
2.0
2.0
2.0
2.0
2.0
2.0
2.0
1.2
-
-
-
-
2.0
2.0
2.0
0.75
FRN0005G2S-2G
-
2.0
2.0
2.0
4.0
2.0
2.0
2.0
1.6
-
-
-
-
1.5
FRN0008G2S-2G
-
2.0
2.0
2.0
7.5
2.0
2.0
2.0
3.6
-
-
-
-
2.2
FRN0011G2S-2G
-
2.0
2.0
2.0
11.0
2.0
2.0
2.0
3.5
-
-
-
-
3.7
FRN0018G2S-2G
-
2.0
2.0
2.0
18.4
2.0
2.0
2.0
4.1
-
-
-
-
5.5
FRN0032G2S-2G
-
3.5
2.0
2.0
25.9
2.0
2.0
2.0
6.4
-
-
-
-
3.5
3.5
3.5
7.5
FRN0046G2S-2G
FRN0032G2S-2G
5.5
3.5
3.5
35.3
2.0
2.0
2.0
6.1
2.0
2.0
2.0
6.4
5.5
5.5
5.5
11
FRN0059G2S-2G
FRN0046G2S-2G
14.0
5.5
5.5
51.7
2.0
2.0
2.0
9.1
2.0
2.0
2.0
6.1
5.5
5.5
5.5
15
FRN0075G2S-2G
FRN0059G2S-2G
14.0
14.0
8 *3
70.6
2.0
2.0
2.0
11
2.0
2.0
2.0
9.1
8 *3
8 *3
8 *3
18.5
FRN0088G2S-2G
FRN0075G2S-2G
22.0
14.0
14.0
87.0
2.0
2.0
2.0
14
2.0
2.0
2.0
11.0
8 *3
8 *3
8 *3
22
FRN0115G2S-2G
FRN0088G2S-2G
38 *1
22.0
14.0
103
2.0
2.0
2.0
15
2.0
2.0
2.0
14.0
14
14
14
30
-
FRN0115G2S-2G
60 *2
38 *1
22.0
140
-
-
-
-
2.0
2.0
2.0
15.0
14
14
14
FRN0146G2S-2G
-
60
38
22
140
2
2
2
19
-
-
-
-
14
14
14
37
FRN0180G2S-2G
FRN0146G2S-2G
60
38
38
169
3.5
2
2
25
2
2
2
19
22
22
22
45
FRN0215G2S-2G
FRN0180G2S-2G
100
60
38
205
3.5
3.5
2
30
3.5
2
2
25
22
22
22
55
FRN0288G2S-2G
FRN0215G2S-2G
150
100
60
249
5.5
3.5
3.5
37
3.5
3.5
2
30
22
22
22
75
-
FRN0288G2S-2G
200
150
100
345
-
-
-
-
5.5
3.5
3.5
37
22
22
22
FRN0346G2S-2G
-
200
150
100
346
8
5.5
5.5
48
-
-
-
-
22
22
22
90
-
FRN0346G2S-2G
250
150
150
409
-
-
-
-
8
5.5
5.5
48
22
22
22
FRN0432G2S-2G
-
250
150
150
410
14
8
5.5
61
-
-
-
-
22
22
22
110
-
FRN0432G2S-2G
325
200
150
502
-
-
-
-
14
8
5.5
61
38
38
38
(Note 1) “IV wire” is used for permissible temperature of 60 °C (140 °F), "600 V HIV insulated wire” is used for 75 °C
(167 °F), and “600 V cross-linked polyethylene insulated wire” is used for 90 °C (194 °F). These values
are for aerial wiring.
(Note 2) A braking unit (BU) (option) is necessary for FRN0346G2S-2G and above.
*1) For compatible crimped terminals, please use model 38-6 by JST Mfg. Co., Ltd. or equivalent.
*2) For compatible crimped terminals, please use model 60-6 by JST Mfg. Co., Ltd. or equivalent.
*3) For compatible crimped terminals, please use model 8-L6 by JST Mfg. Co., Ltd. or equivalent.
*4) Not applicable
*5) Not applicable
*6) Not applicable
*7) Not applicable

Table of Contents

Related product manuals