11.2 Size of Current for Each Part of the Inverter
11-3
SELECTING PERIPHERAL EQUIPMENT
Chap 11
Table 11.2-1 Size of current for each part of inverter (cont.)
HHD specification: Heavy Duty applications
HND specification: Normal Duty applications
Power system
Specification
Standard applicable
motor (kW) [HP]
Inverter type
50 Hz, 400 V
60 Hz, 440 V
Braking
resistor
circuit
current (A)
Input RMS current (A)
DC intermediate
circuit current (A)
Input RMS current (A)
DC intermediate
circuit current (A)
DC reactor (DCR)
DC reactor (DCR)
Yes
N/A
Yes
N/A
Three-phase 400 V
HHD
0.4 [1/2]
FRN0002G2□-4G
0.85
1.7
1
0.74
1.7
0.99
0.8
HHD
0.75 [1]
FRN0003G2□-4G
1.6
3.1
2.0
1.5
2.9
1.9
1.1
HHD
1.5 [2]
FRN0004G2□-4G
3.0
5.9
3.7
2.8
5.4
3.5
1, 8
HHD
2.2 [3]
FRN0006G2□-4G
4.5
8.2
5.6
4.1
7.5
5.1
1, 8
HHD
3.7 [5]
FRN0009G2□-4G
7.5
13
9.2
6.9
11.8
8.5
2.1
HHD
5.5 [7.5]
FRN0018G2□-4G
10.6
17.3
13.0
9.6
15.7
11.8
3.2
HND
7.5 [10]
14.4
23.2
17.7
13.0
21.0
16.0
3.2
HHD
7.5 [10]
FRN0023G2□-4G
14.4
23.2
17.7
13.0
21.0
16.0
3.1
HND
11 [15]
21.1
33.0
25.9
19.0
29.8
23.3
3.1
HHD
11 [15]
FRN0031G2□-4G
21.1
33.0
25.9
19.0
29.8
23.3
4.5
HND
15 [20]
28.8
43.8
35.3
26.0
39.5
31.9
4.5
HHD
15 [20]
FRN0038G2□-4G
28.8
43.8
35.3
26.0
39.5
31.9
5.7
HND
18.5 [25]
35.5
52.3
43.5
32.0
47.1
39.2
5.7
HHD
18.5 [25]
FRN0045G2□-4G
35.5
52.3
43.5
32.0
47.1
39.2
7.2
HND
22 [30]
42.2
60.6
51.7
38.0
54.6
46.6
7.2
HHD
22 [30]
FRN0060G2□-4G
42.2
60.6
51.7
38.0
54.6
46.6
7.7
HND
30 [40]
57.0
77.9
69.9
51.4
70.2
63.0
7.7
HHD
30 [40]
FRN0075G2□-4G
57.0
77.9
69.9
51.4
70.2
63.0
10
HND
37 [50]
68.5
94.3
83.9
61.8
85.0
75.7
10
HHD
37 [50]
FRN0091G2□-4G
68.5
94.3
83.9
61.8
85.0
75.7
12
HND
45 [60]
83.2
114
102
75.0
103
91.9
12
HHD
45 [60]
FRN0112G2□-4G
83.2
114
102
75.0
103
91.9
15
HND
55 [75]
102
140
125
91.9
126
113
15
HHD
55 [75]
FRN0150G2□-4G
102
140
125
91.9
126
113
19
HND
75 [100]
138
-
169
124
-
152
19
HHD
75 [100]
FRN0180G2□-4G
138
169
124
152
24
HND
90 [125]
164
201
148
181
24
HHD
90 [125]
FRN0216G2□-4G
164
201
148
181
31
HND
110 [150]
201
246
181
222
31
HHD
110 [150]
FRN0260G2□-4G
201
246
181
222
35
HND
132 [200]
238
292
214
263
35
HHD
132 [200]
FRN0325G2□-4G
238
292
214
263
42
HND
160 [250]
286
350
258
315
42
HHD
160 [250]
FRN0377G2□-4G
286
350
258
315
50
HND
200 [300]
357
437
321
394
50
HHD
200 [300]
FRN0432G2□-4G
357
437
321
394
62
HND
220 [350]
390
478
351
430
62
(Note) □ in the inverter type is replaced by a letter of the alphabet.
S (basic type), E (type with built-in EMC filter)
Inverter efficiency is calculated using values suitable for each inverter model. Furthermore, input RMS current
is calculated based on the following conditions.
[FRN0060G2-4G or lower] Power supply capacity: 500 kVA, source impedance: 5%
[FRN0075G2-4G or higher] Values commensurate with the capacity recommended by Fuji Electric are
used for calculating the power supply capacity and source impedance.
The input RMS currents listed in the above table will vary in inverse proportion to the power supply voltage,
such as 380 V.
The braking circuit current is always constant, independent of braking resistor type (built-in, standard,