14.2 Diagnostics
To access the General page, on the Healthchecks page, click the General tab (see "General
Page" on page 418).
Figure 292: General Page
The General page displays the following information about the most recently run
healthchecks:
Status The status of the healthchecks (In Progress, Success,
Failed, or Interrupted).
Progress The percentage complete of the healthchecks.
Start Time The time the healthchecks started.
End Time The time the healthchecks ended.
Use the General page to perform the following tasks:
l To start all enabled healthchecks, click Start.
l To stop all healthchecks in progress, click Stop.
Status
The Status page allows you to view information about the most recent test results for each
healthcheck. You can also enable or disable a healthcheck.
The following healthchecks are available:
l De-Duplication - Checks the overall health of the blockpool. This healthcheck verifies
that the metadata in the namespace file and the data tags in the blockpool are
correctly in sync.
l Integrity - Checks the integrity of data in the blockpool. This healthcheck examines a
sample of data tags in the blockpool and verifies that the data has been properly
stored without errors or corruption.
To access the Status page, on the Healthchecks page, click the Status tab (see "Status
Page" on page 419).