5.3 Cabling the ETERNUS CS800 S6 System
Appropriate labels should be already affixed to the cables or can be taken from
the section LAN Cabling (SCALE) of the label sheet, see "CS800 Labelsheet" on
page 88.
2. Connect the host interface adapters CA#1 of both DX100 controller modules to the
server:
Figure 69: FC connection between server and DX100 controller enclosure
a. CM#0 CA#1 port 0 has to be connected to the upper port of the PCI FC card in slot
2.
b. CM#1 CA#1 port 0 has to be connected to the upper port of the PCI FC card in slot
8.
Appropriate labels should be already affixed to the cables or can be taken from
the section FC Cabling (SCALE) of the label sheet, see "CS800 Labelsheet" on page
88.
3. If DX100 drive enclosures are available, connect them to the controller enclosure using
the SAS cables delivered together with the system.
CAUTION!
The sequence of the DX100 storage expansion modules must be observed
precisely when they are mounted and connected to each other, see "Labels on
Front and Rear of the Storage Expansion Module" on page 77. Otherwise the
system will not work and might get damaged.
The SAS cabling of the DX100 storage modules has to be prepared in the form of a so
called reverse cabling: The cabling chain behind CM#0 of the CE module goes from the
first to the last DE while the chain behind CM#1 goes from the last to the first DE.