CHAPTER 3
Small Configuration
Installing the Optical/Tributary Shelf
3-39
FLASHWAVE 7500 Release 6.1
Equipment Installation
Fujitsu and Fujitsu Customer Use Only
FNC-7500-0061-200
Issue 1, May 2009
2 Is the Optical/Tributary shelf to be installed in a 19-inch relay rack?
If YES:
Proceed to Step 3 [p. 3-39].
If NO:
Proceed to Step 8 [p. 3-42].
3 Get the flange kit for 19-inch rack mounting. Table 3-3 [p. 3-34] lists the flange kit part
numbers.
4 Identify the left and right shelf flanges. See Figures 3-19 [p. 3-35] and 3-23 [p. 3-39].
Note: At first glance the two flanges for 19-inch rack mounting appear to be identical, but they are
not. See Figure 3-23 [p. 3-39]. When properly mounted, the cutout appears at the front of the shelf
(see Figure 3-24 [p. 3-40]) and flange holes align with the shelf mounting holes (see Figure 3-25
[p. 3-41]).
Left Shelf Flange Right Shelf Flange
Figure 3-23: Optical/Tributary Shelf Mounting Flanges for 19-Inch Rack Mounting
(Front and Side Views)
L
m1656sz_3
R
m1656ta_3
Revision 1, June 2009