CHAPTER 4
ETSI Configuration
Installing Fans, Rack Covers, and End Panels
4-57
FLASHWAVE 7500 Release 6.1
Equipment Installation
Fujitsu and Fujitsu Customer Use Only
FNC-7500-0061-200
Issue 1, May 2009
9 Install two of each type of standoff in the mounting holes identified in Step 8 [p. 4-55] as
shown in the figure. Ensure that the applicable external tooth washers and flat washers are
installed on the standoffs before you tighten them. See Figures 4-40 [p. 4-57] and 4-41
[p. 4-58].
Figure 4-40: Upper Cover Mounting Screws/Standoffs with Upper FLASHWAVE 7500 Shelf
r1432_1
Replace mounting screws in top
two indicated locations with:
2 PC210-0001-X028 standoffs, pin/hook
2 D4-WTE250-33 external tooth washers
Replace mounting screws in bottom
two indicated locations with:
2 PC210-0001-X027 standoffs, pin/socket
2 D4-WTE250-33 external tooth washers