CHAPTER 6
Installing/Removing Modules, Filler Panels and Plug-In Units
Installing/Removing SFP Modules in a Muxponder or Flexponder™ Unit
6-13
FLASHWAVE 7500 Release 6.1
Equipment Installation
Fujitsu and Fujitsu Customer Use Only
FNC-7500-0061-200
Issue 1, May 2009
2 Is an installed SFP module to be removed from the muxponder plug-in unit?
If YES:
Continue with Step 3 [p. 6-13].
If NO:
Proceed to Step 4 [p. 6-14].
3 For a muxponder unit, completely loosen the two thumb screws on the front of the plug-in
unit. These screws secure the stainless steel client connection drawer. See Figures 6-7 [p. 6-13]
and 6-8 [p. 6-14]. Gently pull the thumb screws forward to open the drawer and expose the
SFP modules and client fiber connections, if present. Proceed to Step 5 [p. 6-15].
Figure 6-7: IFMA-8TCx Muxponder Unit with Client Connection Drawer Open
r0433.fh10_1
Revision 1, June 2009