118
Chapter 4 Operations after OS Installation
9 Click [OK] to close the property window for the LAN adapter.
When the Teaming setting is complete, the following virtual adapter will be created.
"Team: (Team Name)"
Upper protocols will be bound with the main virtual adapter.
They cannot be bound with the LAN card included in a Team.
The IP address can be set in the main virtual adapter.
Event logs
When configuring a team, the following event logs will be generated (source: iANSMiniport).
table: Event log messages
ID Type Message
3 Error The necessary registry parameter could not be read. To resolve this problem, delete the
adapter team, and create a new team.
6 Information The primary adapter has been initialized: (Adapter name)
7 Information The adapter has been initialized: (Adapter name)
8 Information (Team name): The team has been initialized.
10 Information The current primary adapter is changed from the next adapter: (Adapter name)
11 Warning The next adapter link is not connected: (Adapter name)
12 Information The secondary adapter has a priority: (Adapter name)
13 Warning (Adapter name) has been disabled with a team.
14 Information The secondary adapter has been added to a team again: (Adapter name)
15 Information The next adapter link is connected: (Adapter name)
16 Warning (Team name): The last adapter has been unlinked. The team network connection has
failed.
17 Information (Team name): The adapter has established a link again. The team network connection has
been recovered.
18 Information The primary adapter at the next priority level has been detected: (Adapter name)
19 Information The secondary adapter at the next priority level has been detected: (Adapter name)
20 Information The primary adapter at the next priority level is preferentially handled: (Adapter name)
21 Information The secondary adapter at the next priority level is preferentially handled: (Adapter name)
22 Warning The primary adapter could not detect the next probe: (Adapter name) Cause: The team
may be divided into groups.
35 Warning (Team name) without one adapter is initialized. Confirm that all adapters exist and
function.
38 Information (Adapter name) has been deleted from the team.
42 Warning (Adapter name) is not specified properly. The adapter cannot process the remote
management function while being a network team.