Chapter 3 Troubleshooting 3-7
3.3.2.1 Checking the Software Configuration
The following procedure can be used to check the software configuration from the
domain console.
Type showrev.
The showrev command displays system configuration information on the screen.
3.3.2.2 Checking the Firmware Configuration
Login authority is required to check the firmware configuration. The procedure
below can be used to check the configuration from the maintenance terminal.
1. Log in with the account of the XSCF hardware field engineer.
2. Type version.
The version command displays firmware version information on the screen. For
details, see the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF
User's Guide.
3.3.2.3 Downloading Error Log Information
To download error log information, use the XSCF log fetch function. The XSCF unit
has an interface with external units so that the authorized service personnel can
easily obtain useful maintenance information such as error logs.
Connect the maintenance terminal, and use the XSCF Shell or XSCF Web to
download error log information to the maintenance terminal.
# showrev
XSCF> version

Table of Contents

Other manuals for Fujitsu SPARC Enterprise M3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu SPARC Enterprise M3000 and is the answer not in the manual?

Fujitsu SPARC Enterprise M3000 Specifications

General IconGeneral
BrandFujitsu
ModelSPARC Enterprise M3000
CategoryServer
LanguageEnglish

Related product manuals