3-14 SPARC Enterprise M3000 Server Service Manual March 2012
3.5.2 Using the showlogs Command
The showlogs command displays information of specified logs in the order of time
stamps. The information with the oldest time stamp is displayed first. The
showlogs command displays the following logs:
Error log
Power log
Event log
Temperature and humidity record
Monitoring message log
Console message log
Panic message log
IPL message log
XSCF> showlogs error
Date: Jun 17 11:05:32 JST 2008 Code: 80000000-c3ff0000-0173000600000000
Status: Alarm Occurred: Jun 17 11:05:32.522 JST 2008
FRU: /PSU#1
Msg: PSU shortage
Date: Jun 17 13:41:46 JST 2008 Code: 80002080-7801c201-0130000000000000
Status: Alarm Occurred: Jun 17 13:41:44.861 JST 2008
FRU: /MBU_A,*
Msg: Board control error (MBC link error)
Date: Jun 17 13:46:31 JST 2008 Code: 60000000-cd01c701-0164010100000000
Status: Warning Occurred: Jun 17 13:46:31.158 JST 2008
FRU: /OPNL,/FANBP_B
Msg: TWI access error
XSCF>

Table of Contents

Other manuals for Fujitsu SPARC Enterprise M3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu SPARC Enterprise M3000 and is the answer not in the manual?

Fujitsu SPARC Enterprise M3000 Specifications

General IconGeneral
BrandFujitsu
ModelSPARC Enterprise M3000
CategoryServer
LanguageEnglish

Related product manuals