F-1
APPENDIX
F
Reactivating a Hardware RAID Boot
Volume
This appendix explains how to reactivate a hardware RAID boot volume after
replacing the MBU of an M3000 server with the SPARC64 VII+ processors. Non-boot
RAID volumes can be reactivated after booting with the Oracle Solaris raidctl
command.
The MBU contains the RAID controller. When the MBU is replaced, the disks
comprising the RAID boot volume must be reactivated to be able to boot. This is
done from OBP via the OBP command activate-volume.
1. Confirm that the RAID volume is no longer listed.
{0} ok probe-scsi-all
pci@0,600000/pci@0/pci@0/scsi@0
MPT Version 1.05, Firmware Version 1.31.00.00
arget 4
Unit 0 Removable Read Only device TEAC DV-W28S-V J.0B
SATA device PhyNum 4