Chapter 3 Troubleshooting 3-17
3.5.4.2 fmdump -e Command
To get information of the errors that caused this failure you can use the -e option, as
shown in the following example.
3.5.5 Using the fmadm Command
3.5.5.1 Using the fmadm faulty Command
The fmadm faulty command can be used by administrators and service personnel to
view and modify system configuration parameters that are maintained by the Oracle
Solaris Fault Manager. The command is primarily used to determine the status of a
component involved in a fault, as shown in the following example:
The PCIe slot has been degraded and it is associated with the same UUID as above.
Also, the "faulted" status may be displayed.
# fmdump -e
TIME CLASS
Nov 02 10:04:14.3008 ereport.io.fire.jbc.mb_per
# fmadm faulty
STATERESOURCE / UUID
-------- --------------------------------------------------------
degraded dev:////pci@1e,600000
0ee65618-2218-4997-c0dc-b5c410ed8ec2
# fmadm repair
0ee65618-2218-4997-c0dc-b5c410ed8ec2