Appendix B XSCF Log Information B-3
â–  Time at which each problem occurred (Occurred). This is indicated in local time.
â–  Replacement component (FRU) that is probably faulty. A comma (,) separates two
suspect components displayed. For additional suspect components, an "*"
(asterisk) is displayed after the comma (,). Each component is displayed
hierarchically in a component mounting path format. Whether more suspect
components are to be displayed depends on the position where the fault was
detected.
The following explains cases where "FRU:" is displayed.
(a) "PSU#1, PSU#2" is displayed.
The above indicates the following: PSU#1 and PSU#2 were detected as the first and
second suspect components, respectively. It might be necessary to replace the
respective components as circumstances require.
(b) "PSU#1, PSU#2,*" is displayed.
The above indicates the following: PSU#1 and PSU#2 were detected as the first and
second suspect components, respectively, with other components also detected. It
might be necessary to replace the respective components.
(c) "IOU#0/PCI#3" is displayed.
The above indicates the following: IOU#0/PCI#3 was detected as the suspect
component, and PCI slot No.3 of I/O unit No.0 is problematic. It might be necessary
to replace the device connected to PCI slot No.3 as circumstances require.
(d) "MBU_A/MEMB#0/(MEM#02A)" is displayed.
The above indicates the following: MBU_A/MEMB#0/MEM#02A was detected as
the suspect component, and memory slot No.02A of memory board No.0 on the
MBU is problematic. It may be necessary to replace memory slot No.02A as
circumstances require.
(e) "CMU#0/MEM#02A" is displayed.
The above indicates the following: CMU#0/MEM#02A was detected as the suspect
component, and memory slot No.02A of CMU 0 is problematic. It may be necessary
to replace memory slot No.02A as circumstances require.
(f) "CMU#0/MEM#02A-02B" is displayed.
Alarm: The relevant component failed.
Warning: Some subcomponents in the relevant component failed or degraded.
Information: Notification.
Notice: System state notification.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu SPARC EnterpriseM3000 and is the answer not in the manual?

Fujitsu SPARC EnterpriseM3000 Specifications

General IconGeneral
BrandFujitsu
ModelSPARC EnterpriseM3000
CategoryServer
LanguageEnglish

Related product manuals