EasyManuals Logo

Furuno NAVpilot-711C User Manual

Furuno NAVpilot-711C
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #72 background imageLoading...
Page #72 background image
3. ALARMS
3-6
3.10 Water Temperature Alarm
The water temperature alarm warns you when the water temperature is within, out-
side, over or under the temperature range setting. Also, it is available to alert you when
temperature changes over the value set within a minute. Requires a water tempera-
ture sensor.
1. Open the [Alarm] menu.
2. Rotate the Course control knob to select the current setting for
[Temp Alarm] then push the knob.
The window shown right appears.
3. Rotate the Course control knob to select an option then push
the knob. For [OFF], go to step 6.
[OFF]: Turn the alarm off.
[Under]: Alarm sounds when water temperature is less than the
set value.
[Over]: Alarm sounds when water temperature is higher than the set value.
[Inside]: Alarm sounds when water temperature is within the range set.
[Out of Range]: Alarm sounds when water temperature is outside the range set.
[Shear]: Alarm sounds when the temperature changes over the value set within a
minute.
4. Rotate the Course control knob to select the current setting value then push the
knob.
5. Push the Course control knob to set the value then push the knob.
[Over], [Under], [Shear]: Set a value.
[Inside], [Out of Range]: Set the upper and lower limits for the alarm.
6. Press the key three times to close the menu.
OFF
Under
Over
Inside
Out of Range
Shear

Table of Contents

Other manuals for Furuno NAVpilot-711C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno NAVpilot-711C and is the answer not in the manual?

Furuno NAVpilot-711C Specifications

General IconGeneral
BrandFuruno
ModelNAVpilot-711C
CategoryAutopilot System
LanguageEnglish

Related product manuals