86 0000010291
001
7.3 Observed deviations
7.3.1 Machine problems
7.3.1.1 Operator
7.3.1.2 Service personnel
Problem Possible cause Solution (See)
Knockout cylinder does
not go down.
The knockout time is too short for
the knockout to make a full
stroke.
Set a longer
knockout time.
Problem Possible cause Solution (See)
Knockout cylinder does
not go down.
The sensor on the knockout is
defective.
Repair or re-
place.
Air pressure or air flow to the
knockout cylinders too low.
7.3.3
The knockout cylinders are de-
fective.
Repair or re-
place.
Knockout cylinder does
not go up.
The sensor on the knockout is
defective.
Repair or re-
place.
The air pressure or air flow to the
knockout cylinders is too low.
7.3.3
The knockout cylinders are de-
fective.
Repair or re-
place.
The form plate connec-
tion bracket is damaged.
Accident. 7.3.7
Loud mechanical noise
of the hydraulic cylinder.
Wear of the end-buffer Adjust the flow
control valve of
the end-buffer.
7.3.9
Fork of the bridge-break-
er does not rotate.
The pawl does not catch the
gearwheel.
Adjust the deten
tion rubber or re-
place the pawl,
7.3.10 .