A10.00 Start SM mon N/A R 0 0/1 DV V-F-S Full 163
Drive Start status.
0 OFF
1 ON
A11.00 FStop SM mon N/A R 0 0/1 DV V-F-S Full 164
Drive FastStop status
0 OFF
1 ON
A12 DISPLAY / IO Dsply
A12.00 DI 7654321E N/A R 0 0/1 DP V-F-S Easy 4028
Standard digital inputs status, from 0 to 7; E (Enable) = Digital Input 0
A12.01 DO 3210 N/A R 0 0/ 1 DP V-F-S Easy 4064
Standard digital outputs status, from 0 to 3
A12.02 DIX BA9876543210 N/A R 0 0/1 DP V-F-S Full 4057
Expanded digital inputs status, from 0 to 11;
A = Digital InputX 10, B = Digital InputX 11 (X suffix means expanded)
A12.03 DOX 76543210 N/A R 0 0/1 DP V-F-S Full 4078
Expanded digital outputs status, from 0 to 7 (X suffix means expanded)
A13 DISPLAY / Adv Dsply
A13.00 Magnetiz curr [A] R 0.00 0.00/0.00 PV V-F-S Easy 3110
Drive magnetizing current
A13.01 Torque curr [A] R 0.00 0.00/0.00 PV V-F-S Easy 3120
Drive torque current
A13.02 Std Enc Spd [rpm] R 0.00 0.00/0.00 PV V-F-S Easy 3222
Encoder speed of standard feedback (connector “XE”on RV33 regulation board)
A13.03 Exp Enc Spd [rpm] R 0.00 0.00/0.00 PV V-F-S Easy 3223
Encoder speed of expanded feedback (encoder connector on expansion optional boards).
A13.04 HT sensor temp [°C] R 0.00 0.00/0.00 PV V-F-S Easy 9072