ARTDrive V2 series - Instruction Manual Chapter 6 Parameter • 129
The status of the digital selector is read by the drive only when the output of the inverter
bridge is disabled. As a result, it is not possible to switch between local and remote
source for main commands while the motor is running.
NOTE! Normally the Stop key acts as Emergency stop, when the source of main
commands is not the keypad.
For more details, see C00-24 parameter description below.
C00.04 Dig Enable src N/A RWS Ipa4000 PList 17 PIN V-F-S-B Full 156
Ipa 4000 - NULL = Default
It allows to select the signal to generate a digital Enable command.
ªª
ªª
ª
Pick List 17
C00.05 Dig StrStp src N/A RWS Ipa4000 PList 17 PIN V-F-S-B Full 157
Ipa 4000 - NULL = Default
It allows to select the signal to generate the a digital Start (1) command and a digital Stop
(0) command.
ªª
ªª
ª
Pick List 17
C00.06 FastStop src N/A RWS Ipa4000 PList 18 PIN V-F-S-B Easy 154
Ipa 4000 - NULL = Default
It allows to select the signal to generate the FastStop command.
ªª
ªª
ª
Pick List 18
C00.07 ForwardStart src N/A RWS (*) Plist 03 PIN V-F-S-B Easy 8083
(*) Ipa 4001 - [1] ONE = Default (Europe)
Ipa 4021 - [2] DI 1 mon = Default (American)
It allows to select the signal of Forward command of 2-wires and FRC or Start command
of 3-wires; see C00.25 - FRC cmd mode description below.
ªª
ªª
ª
Pick List 3
C00.08 Reverse src N/A RWS (*) Plist 03 PIN V-F-S-B Easy 8084
(*) Ipa 4001 - ONE = Default (Europe)
Ipa 4022 - DI 2 = Default (American)
It allows to select the signal of Reverse command; see “ C00.25 - FRC cmd mode”
description below.