MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual Chapter 6 Parameter • 133
C00.26 FRC reverse N/A R 0 0/1 DV V-F-S-B Easy 8081
It displays the output reverse signal of FRC block
C00.27 FRC alarm N/A R 0 0/1 DV V-F-S-B Easy 8082
It displays the output Alarm signal of FRC block
C00.28 FRC Start mon N/A R 0 0/1 DV V-F-S-B Easy 8086
It displays the output Start signal of FRC block
C00.29 FRC cmd mon N/A R 0 0/1 DV V-F-S-B Full 8080
It displays the Forward Reverse Control command signal; if C00.25 = [0] normal FWD is
LSB; Rev is MSB
C00.40 EnableSM mon N/A R 0 0/1 DV V-F-S-B Full 150
It displays the Enable command state
C00.41 Start SM mon N/A R 0 0/1 DV V-F-S-B Full 151
It displays the Start command state
C00.42 FStop SM mon N/A R 0 0/1 DV V-F-S-B Full 152
It displays the FastStop command state
C00.43 Local cmd mon N/A R 0 0/1 DV V-F-S-B Full 166
It displays the Local command signal; see “C00.03 - Term Local src” description above.