MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 150 ARTDrive V2 series - Instruction Manual
ªª
ªª
ª
Pick List 2
C14.10 AO 4X type N/A RWS 0 0/1 DP V-F-S-B Full 6039
It allows to select the Analog output 4X type (EXP-D20A6 optional card is required);
below are shown the selections:
[0] 0..20 mA
[1] 4..20 mA
C14.11 AO 4X scale N/A RWS 1 -10 1/0 PP V-F-S-B Full 6037
Scale or multiplicative factor of Analog output 2X.
C14.12 AO 4X high lim [cnt] RWS 16383 0/32767 PP V-F-S-B Full 6035
Analog output 4X count value aimed at obtaining +10V. Value must be higher than zero.
C14.13 AO 4X low lim [cnt] RWS -16384 -32768/0 PP V-F-S-B Full 6036
Analog output 4X count value aimed at obtaining -10V. Value must be higher than zero.
C14.20 AO 4X inp [cnt] R 0 -32768/32767 PP V-F-S-B Full 6038
Analog output 4X count value displaying.
C14.21 AO 4X mon [%] R 0 -100/100 PP V-F-S-B Full 6009
Analog output 4X value 100% is equal to 20mA.