Index
MENUMENU
MENUMENU
MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual Chapter 6 Parameter • 149
C13 INTERFACE / An Out 3X
See Analog Output 1 diagram and description above.
NOTE! This output is current type.
C13.00 AO 3X src N/A RWS Ipa4000 PList 2 PIN V-F-S-B Full 4092
Ipa 4000 - NULL = Default
It allows to connect the selected signal to the Analog output 3X.
ªª
ªª
ª
Pick List 2
C13.10 AO 3X type N/A RWS 0 0/1 DP V-F-S-B Full 6034
It allows to select the Analog output 3X type (EXP-D20A6 optional card is required);
below are shown the selections:
[0] 0..20 mA
[1] 4..20 mA
C13.11 AO 3X scale N/A RWS 1 -10 1/0 PP V-F-S-B Full 6032
Scale or multiplicative factor of Analog output 2X.
C13.12 AO 3X high lim [cnt] RWS 16383 0/32767 PP V-F-S-B Full 6030
Analog output 3X count value aimed at obtaining +10V. Value must be higher than zero.
C13.13 AO 3X low lim [cnt] RWS -16384 -32768/0 PP V-F-S-B Full 6031
Analog output 3X count value aimed at obtaining -10V. Value must be higher than zero.
C13.20 AO 3X inp [cnt] R 0 -32768/32767 PP V-F-S-B Full 6033
Analog output 3X count value displaying.
C13.21 AO 3X mon [%] R 0 -100/100 PP V-F-S-B Full 6008
Analog output 3X value 100% is equal to 20mA.
C14 INTERFACE / An Out 4X
See Analog Output 1 diagram and description above.
NOTE! This output is current type.
C14.00 AO 4X src N/A RWS Ipa4000 PList 2 PIN V-F-S-B Full 4093
Ipa 4000 - NULL = Default
It allows to connect the selected signal to the Analog output 4X.