C11.10 AO 1X scale N/A RWS 1 -10 1/0 PP V-F-S-B Full 6022
Scale or multiplicative factor of Analog output 1X
C11.11 AO 1X high lim [cnt] RWS 16383 0/32767 PP V-F-S-B Full 6020
Analog output 1X count value aimed at obtaining +10V. Value must be higher than zero.
C11.12 AO 1X low lim [cnt] RWS -16384 -32768/0 PP V-F-S-B Full 6021
Analog output 1X count value aimed at obtaining -10V. Value must be higher than zero.
C11.20 AO 1X inp [cnt] R 0 -32768/32767 PP V-F-S-B Full 6023
Analog output 1X count value displaying.
C11.21 AO 1X mon [%] R 0 -100/100 PP V-F-S-B Full 6024
Analog output 1X value displaying 100% is equal to 10V.
C12 INTERFACE / An Out 2X
See Analog Output 1 diagram and description details above.
C12.00 AO 2X src N/A RWS Ipa4000 PList 2 PIN V-F-S-B Full 4091
Ipa 4000 - NULL = Default
It allows to connect the selected signal to the Analog output 2X.
ªª
ªª
ª
Pick List 2
C12.10 AO 2X scale N/A RWS 1 -10 1/0 PP V-F-S-B Full 6027
Scale or multiplicative factor of Analog output 2X.
C12.11 AO 2X high lim [cnt] RWS 16383 0/32767 PP V-F-S-B Full 6025
Analog output 2X count value aimed at obtaining +10V. Value must be higher than zero.
C12.12 AO 2X low lim [cnt] RWS -16384 -32768/0 PP V-F-S-B Full 6026
Analog output 2X count value aimed at obtaining -10V. Value must be higher than zero.
C12.20 AO 2X inp [cnt] R 0 -32768/32767 PP V-F-S-B Full 6028
Analog output 2X count value displaying.
C12.21 AO 2X mon [%] R 0 -100/100 PP V-F-S-B Full 6029
Analog output 2X value displaying 100% is equal to 10V.