MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual Chapter 6 Parameter • 175
D00.03 Ramp ref inv src N/A RWS Ipa4000 PList 3 PIN V-F-S-B Easy 7037
Ipa 4000 - NULL = Default
It connects the selected signal to the selector of the multiplier input: if the signal is 0,
multiply by +1, or if the signal is 1, multiply by –1. The multiplier allows to invert Ramp
reference signal
ªª
ªª
ª
Pick List 3
D00.10 Dig ramp ref 1 [rpm] RWS 0 Calc/Calc PV V-F-S-B Easy 7030
Value of the Digital ramp reference 1 variable, selectable through Pick List 17 of D00.00 -
Ramp ref 1 src.
D00.11 Dig ramp ref 2 [rpm] RWS 0 Calc/Calc PV V-F-S-B Easy 7031
Value of the Digital ramp reference 2 variable, selectable through Pick List 8 of D00.01 -
Ramp ref 2 src..
D00.12 Dig ramp ref 3 [rpm] RWS 0 Calc/Calc PV V-F-S-B Full 7038
Value of the Digital ramp reference 3 variable, selectable through Pick List 45 of D00.03 -
Ramp ref 3 src.
D00.20 Ramp ref 1 mon [rpm] R 0.00 0.00/0.00 PP V-F-S-B Full 7032
Displaying of the Ramp ref 1 signal
D00.21 Ramp ref 2 mon [rpm] R 0.00 0.00/0.00 PP V-F-S-B Full 7033
Displaying of the Ramp ref 2 signal
D00.22 Ramp ref 3 mon [rpm] R 0.00 0.00/0.00 PP V-F-S-B Full 7039
Displaying of the Ramp ref 3 signal
D00.23 Ramp setpoint [rpm] R 0.00 0.00/0.00 PV V-F-S-B Easy 7034
Displaying of the Ramp setpoint output signal