Index
MENUMENU
MENUMENU
MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual Chapter 6 Parameter • 177
D01.01 Mlt ramp s1 src N/A RWS Ipa4000 PList 3 PIN V-F-S-B Easy 8091
Ipa 4000 - NULL = Default
Multi ramp selector 1 source: it allows to select the origin of the signals stating the input
combination.
ªª
ªª
ª
Pick List 3
Mlt Ramp s1 src Mlt Ramp s0 src ACTIVE SET
0 0 MRamp set 1
0 1 MRamp set 2
1 0 MRamp set 3
1 1 MRamp set 4
tab_D01-01
Table D01.01: Multi ramp setting
Mlt ramp s1 src
Mlt ramp s0 src
Mlt ramp sel m
CTRL
MRamp set 1
MRamp set 2
MRamp set 3
MRamp set 4
Acc S curve
Ramp Setpoint
Dec S curve
Figure D01.01-1: Multi ramp block
Ramp Acc State
Ramp
output
Ramp Dec State
1=Accel time
2=Decel time
11
22
n
t
t
t
Figure D01.01-2: Acceleration and Deceleration Ramps