Chapter 6 Parameter • 180 ARTDrive V2 series - Instruction Manual
REF&RAMP / RampFunct
The Function of this Block is to generate the Ramped Speed reference. Such signal is
generated by tracking the reference of the Ramp setpoint block with the Ramp times
defined in the Multi ramp block.
It allows to select the source origin on the input:
Ramp input = 0 which allows to obtain the input zero setting, Ramp output = 0 which
allows to obtain the output zero setting, Ramp freeze which maintains on the output the
reference value independently of the possible variations on the input.
Furthermore, among the parameters it is possible to configure: with Ramp shape the
ramp type, if a Linear or an S-shaped, with Ramp out enable it is possible to disable the
Ramp output only as a reference, that is blocking the output by keeping the signal
active.
When the Drive is enabled, the Block has at its disposal the Catch on the fly function,
capturing a rotating motor.
The function allows to detect the motor speed and to set the output of the Ramp Block at
the same speed as the motor one.
The main application fields are: the reinsertion after an alarm intervention or during the
capturing of a motor already started by a load, etc.
It is possible to monitor the output signal, the output state (if enabled or disabled), the
ramp acceleration or deceleration state and the command state.
D07 REF&RAMP / RampFunct
D07.00 Ramp input=0 N/A RWS Ipa4000 PList 3 PIN V-F-S-B Full 8027
Ipa 4000 - NULL = Default
It select the origin of the signal, which allows to force Ramp input = 0.
ªª
ªª
ª
Pick List 3
D07.01 Ramp output!=0 N/A RWS Ipa4000 PList 3 PIN V-F-S-B Full 8028
Ipa 4000 - NULL = Default
It select the origin of the signal, which allows to force Ramp output = 0.
ªª
ªª
ª
Pick List 3
D07.02 Ramp freeze N/A RWS Ipa4000 PList 3 PIN V-F-S-B Full 8029
Ipa 4000 - NULL = Default
It select the origin of the signal, which allows to force Ramp freeze.
ªª
ªª
ª
Pick List 3