MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 212 ARTDrive V2 series - Instruction Manual
SPEED REG / Speed Regulator Config
The Block Function, Regulator of the PI Speed (Proportional Integrative), is only active in
a Sensorless and Field Oriented mode.
Among its functions the Block is set to work together with the Speed/Torque regulation
Block (OR regulator). Through the input sources it is possible to select the origin of the
input signals: Spd I=0 src allows to set at zero, temporary, the Integral regulator section,
while Spd PI=0 src allows to set at zero, temporary, the Proportional Integral
regulator section.
It is possible to enable or disable the Block function (enable/disable ) via the Spd reg
enable parameter.
The gains set in the Adaptive block of the speed regulator gains are active in the speed
regulator itself.
They are set in the REG PARAM / Spd Reg menu where it is possible to set the basic
gain of the P and I sections and their respective % gains.
Speed setpoint
Speed
Droop out
Speed up out
In Use spd P gain %
In Use spd I gain %
Spd PI=0
Spd I=0
Spd reg enable
Spd I=0 mon
SpdPI=0mon
FIgure F01: Speed Regulator Config block
F01 SPEED REG / SpdRegCfg
F01.00 Spd I=0 src N/A RWS Ipa4000 PList 3 PIN F-S-B Easy 7054
Ipa 4000 - NULL = Default
It select the origin of enabling signal of Integral section block. It is set at zero and stops
its integrating activity.
ªª
ªª
ª
Pick List 3
F01.01 Spd PI=0 src N/A RWS Ipa4000 PList 3 PIN F-S-B Easy 7056
Ipa 4000 - NULL = Default
It select the origin of enabling signal of Integral and Proportional section block. It is set at