MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual Chapter 6 Parameter • 213
zero and stops its integrating activity.
ªª
ªª
ª
Pick List 3
F01.10 Spd reg enable N/A RWSZ 1 0/1 DP V-F-S-B Easy 7059
Enabling of the speed regulator:
[0] Disabled
[1] Enabled
F01.20 Spd I=0 mon N/A R 0 0/1 PV F-S-B Full 7055
State monitor for the command Spd I=0.
F01.21 Spd PI=0 mon N/A R 0 0/1 PV F-S-B Full 7057
State monitor for the command Spd PI=0.
F02 SPEED REG / Spd ratio
NOTE! Menu accessible with Access Level = FULL
The block function allows to set the speed ratio value, through F02.01 - Speed ratio src
source. F02.02 - Dig spd Ratio with a % value is standard connected, but, anyway, also
the connection of analog and digital signals is possible.
Its default value is 100%, corresponding to the multiply 1 factor.
F02.01 Speed ratio src N/A RWS Ipa7044 Plist13 PIN F-S-B Full 7052
Ipa 7044 - Dig speed ratio = Default
It select the origin of the signal of speed ratio value.
ªª
ªª
ª
Pick List 13
F02.02 Dig spd Ratio [%] RWS 100 0/200 PV F-S-B Full 7044
Digital speed ratio value, selectable through Pick List 13 of F02.01 - Speed ratio src.
ªª
ªª
ª
Pick List 13
F02.03 Speed ratio mon [%] R 0.00 0.00/0.00 PP F-S-B Full 7048
Displaying of Speed ratio signal.