ARTDrive V2 series - Instruction Manual Chapter 6 Parameter • 259
L17 ALARM CFG / FwRevCtrl
It trips when the Forward Reverse control “truth table” is not satisfied; see C00.25 - FRC
cmd mode description in the INTERFACE menu section.
L17.00 FRC activity N/A RWS 3 1/6 DP V-F-S-B Easy 9086
Forward Reverse control activity:
[1] Ignore
[2] Warning
[3] Disable drive
[4] Stop
[5] Fast stop
[6] Curr limstp
L17.01 FRC hold off [ms] RWS 32 0/30000 PP V-F-S-B Easy 9607
Forward Reverse control hold off
L18 ALARM CFG / Over Spd
It trips when the speed of the motor exceeded speed limit threshold.
L18.00 OS activity N/A RWS 3 2/6 DP V-F-S-B Easy 9220
Overspeed activity:
[2] Warning
[3] Disable drive
[4] Stop
[5] Fast stop
[6] Curr limstp
L18.01 OS threshold [rmp] RWS Calc 0.00/Calc PP V-F-S-B Easy 9221
Overspeed threshold.
L18.02 OS hold off [ms] RWS 0 0/30000 PP V-F-S-B Easy 9608
Overspeed hold off.
L19 ALARM CFG / SFbk loss
It trips when the speed feedback is not detected or encoder supply failed.
L19.00 SFL activity N/A RWS 3 1/6 DP V-F-S-B Easy 9042
Spd fbk loss activity:
[1] Ignore
[2] Warning
[3] Disable drive