MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 260 ARTDrive V2 series - Instruction Manual
[4] Stop
[5] Fast stop
[6] Curr limstp
L20 ALARM CFG / UV rep
It trips when more than a programmable number, with L20.00 - UVR attempts parameter,
of Undervoltage faults are detected in 4 minutes (time programmable with L20.01 - UVR
delay parameter)
L20.00 UVR attempts N/A RWS 5 1/1000 PP V-F-S-B Easy 9043
It determines the number of Undervoltage faults accepted.
L20.01 UVR delay [sec] RWS 240 1/262.14 PP V-F-S-B Easy 9044
It determines the time window of L20.00 - UVR attempts parameter.
L21 ALARM CFG / Hw fault
It trips when the communication between drive regulation card and one of its option cards
is not detected.
L21.00 Hw fault mon N/A R 0 0/1 DP V-F-S-B Easy 4202
[0] Communication OK
[1] Communication failed