NOTE! Menu accessible with Access Level = FULL.
P00.00 Cmp 1 inp 0 src N/A RWS Ipa6041 PList 5 PIN V-F-S-B Full 6049
Ipa 6041 - Cmp 1 inp 0 = Default
It allows to select the origin of the input signal 0 to be compared of the Compare 1 block.
ªª
ªª
ª
Pick List 5
P00.01 Cmp 1 inp 1 src N/A RWS Ipa6042 PList 5 PIN V-F-S-B Full 6050
Ipa 6042 - Cmp 1 inp 1 = Default
It allows to select the origin of the input signal 1 to be compared of the Compare 1 block.
ªª
ªª
ª
Pick List 5
P00.02 Cmp 1 inp 2 src N/A RWS Ipa6043 PList 5 PIN V-F-S-B Full 6051
Ipa 6043 - Cmp 1 inp 2 = Default
It allows to select the origin of the input signal 2 to be compared of the Compare 1 block.
ªª
ªª
ª
Pick List 5
P00.10 Cmp 1 inp 0 N/A RWS 0.00 - - PV V-F-S-B Full 6041
Value of the internal input signal 0, default connected to Cmp 1 inp 0 src.
P00.11 Cmp 1 inp 1 N/A RWS 0.00 - - PV V-F-S-B Full 6042
Value of the internal input signal 1, default connected to Cmp 1 inp 1 src.
P00.12 Cmp 1 inp 2 N/A RWS 0.00 - - PV V-F-S-B Full 6043
Value of the internal input signal 2, default connected to Cmp 1 inp 2 src.
P00.20 Cmp 1 function N/A RWS 0 0/10 DP V-F-S-B Full 6044
[0] None
[1] I0 == I1
[2] I0 != I1
[3] I0 < I1
[4] I0 > I1
[5] I0 < I1 < I2
[6] |I0| == |I1|
[7] |I0| != |I1|
[8] |I0| < |I1|

Table of Contents