MENU [Unit] Access Default Min/Max Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual Chapter 6 Parameter • 307
[9] |I0| > |I1|
[10] |I0|< |I1| <|I2|
P00.21 Cmp 1 window [cnt] RWS 0.00 0.00/- PP V-F-S-B Full 6045
It allows to set a window stating an acceptable range among the signals of the Compare
1 block.
P00.22 Cmp 1 delay [sec] RWS 0.00 0.00/30 PP V-F-S-B Full 6046
It allows to set a delay in seconds on the comparison transition in the Compare 1 block.
P00.23 Cmp 1 inversion N/A RWS 0 0/1 DP V-F-S-B Full 6047
Set the inversion on the Compare 1 block output signal:
[0] Not inverted
[1] Inverted
P00.30 Compare 1 out N/A R 0 0/1 DV V-F-S-B Full 6048
It allows to monitor the state of Compare 1 block output signal.
[0] FALSE
[1] TRUE
P01 CUSTOM / Compare 2
NOTE! Menu accessible with Access Level = FULL
P01.00 Cmp 2 inp 0 src N/A RWS Ipa6056 PList 5 PIN V-F-S-B Full 6064
Ipa 6056 - Cmp 2 inp 0 = Default.
It allows to select the origin of the input signal 0 to be compared of the Compare 2 block.
ªª
ªª
ª
Pick List 5
P01.01 Cmp 2 inp 1 src N/A RWS Ipa6057 PList 5 PIN V-F-S-B Full 6065
Ipa 6057 - Cmp 2 inp 1 = Default
It allows to select the origin of the input signal 1 to be compared of the Compare 2 block.
ªª
ªª
ª
Pick List 5