Chapter 7 Appendix • 324 ARTDrive V2 series - Instruction Manual
Figure 7.3.1.1: SLS Gains Profile Signals Optmized
The next figure below shows an example of E08.04 - Sls mot LPgain and
E08.05 - Sls mot LIgain gains signals not optimized.
Increase only E08.04 - Sls mot LPgain gain to match the figure 7.3.1.1.
Figure 7.3.1.2: SLS Low Gains Signals
Now run the motor at medium rpm, 1/2 of motor nominal speed.
The next figure below shows an example of E08.02 - Sls mot MPgain and
E08.03 - Sls mot MIgain gains signals not optimized.
Increase both gain values to match the figure 7.3.1.1.