ARTDrive V2 series - Instruction Manual Chapter 7 Appendix • 325
Figure 7.3.1.3: SLS Medium Gains Signals
Now run the motor at maximum speed (motor nominal speed).
The next figure below shows an example of E08.00 - Sls mot HPgain and
E08.01 - Sls mot HIgain gain signals not optimized.
Increase only E08.00 - Sls mot HPgain gain to match the figure figure
7.3.1.1.
Figure 7.3.1.4: SLS High Gains Signals
NOTE! Regen gains (into menu REG PARAM / Sls Fgains) can be adjusted