56 • Chapter 4 Wiring Procedure ARTDrive V2 series - Instruction Manual
Figure 4.5.1.3: Typical Connection
+ 24V
U1/L1
M1
K1M
5
F1
L1
L2
L3
N
PE
K2
G1
0 V24
C
D
1
2
3
4
6
K1M
SMPS
K0
L1
Thermistor
78
79
B-
1
A+
5
A-
6
B+
8
7
0V
9
5V
XE1
COMID
19
18
16
15
14
13
12
Enable
(Dig. Inp 0)
80
82
83
85
ok
n>0
(default )
RS 485
Keypad
7
8
9
+10 V
-10 V
0 V10
0
FWD
REV
R1
(2 ... 5 kOhm)
2
1
Analog input 1
Analog input
2
-
3
4
-
+
+
Analog input 3
5
6
-
+
E
*) R 1Kohm if
no thermistor
connected
*)
PE1
V1/L2
W1/L3
U2/T1
V2/T2
W2/T3
Dig. Inp.7
Dig. Inp.6
Dig. Inp.5
Dig. Inp.4
Analog
output 2
Analog
output 1
21
22
23
42
46
41
+30 V
Dig. Out.3
Dig. Out.2
27
26
BU
1V3
U3
2V3
Optional from 22 kW up to 55 kW
(for 230...480Vac)
Optional from 25Hpupto40 Hp
(for 575Vac)
M
3~
Note!
U3/2V3 and 1V3 only
from sizes 75 Hp.
For more detailssee
chapter 3.2.1.
36
37
38
39
Dig. Inp.2
Dig. Inp.1
Dig. Inp.3
Dig. Out.1
Dig. Out.0
The circuit diagram is for
the standard configuration
of the drive as delivered.
EMC installation and
wiring techniques are not
shown.
For this see appropriate
chapter. The connection
of option card is also
shown separately.
The automatic restart of
the drive after a failure
alarm is not included.

Table of Contents