Chapter 6 Function Description • 96 ARTDrive V2 series - Instruction Manual
000-Null it connects the signal to Zero, Non-active
001-One it connects the signal to One, Active
………… …………
003-DI 1 mon it connects the signal to the standard digital input
1, being active or non-active is a function of the
digital input state
………… …………
015-DI 0X mon it connects the signal to the expanded dgt 0 input
………… …………
027-B0 W0 decom it connects the signal to a digital bit derived from a
complete word.
D07 REF&RAMP / RampFunct
D07.12 - Ramp shape
The Ramp shape configuration allows to select the Ramp:
0- Linear it sets the Linear Ramp
1- S-Shaped it sets the S Ramp
D07 REF&RAMP / RampFunct
D07.20 - Ramp out mon
It is possible to monitor:
Ramp out mon Output Ramp monitor
…………
D07.24 - Ramp cmds mon
It is possible to monitor:
Ramp cmds mon Ramp Block command monitor
Ramp function Block example
Ramp input=0
Ramp shape Ramp out enable
000-NULL
001-ONE
002-DI 0 En mon
003-DI 1 mon
004-DI 2 mon
005-DI 3 mon
006-DI 4 mon
007-DI 5 mon
008-DI 6 mon
009-DI 7 mon
015-DI 0X mon
016-DI 1X mon
........................
........................
0 - Linear
1 - S-Shaped
1 - Enable
0 - Disable
Ramp out mon
..................
..................
Ramp cmds mon
Ramp setpoint
......................
......................
Pick-list 3
NOTE! Ramp out enable parameter allows to enable or disable the Ramp
output .