ARTDrive V2 series - Instruction Manual Chapter 6 Function Description • 97
Analog signal
Let’s consider a section of the Speed Block. In SPEED REG / Speed ref
menu the source F00.00 - Speed ref 1 src selects the signal origin to the
Speed block input.
Creating the Speed reference. By editing the source the pick-list of the signal
possible sources is displayed.
F00 SPEED REG / Speed ref
F00.00 - Speed ref 1 src
The items of the Speed ref 1 src source (see Pick List 09) are :
000-DigSpd Ref 1 it connects the signal to the Int speed ref 1.
This variable allows the value digital setting, set
internally by keypad or toolbox.
…………
005-AI 2 output connects the signal to the analog input 2 output.
Block to the standard analog input 2.
…………
011-AI 1X output it connects the signal to the expanded analog
input 1.
…………
015-SBIDrvW0 mon it connects the signal to the W0 monitor deriving
from the SBI.
…………
025-ISBusDrvW4 m it connects the signal to the W4 monitor deriving
from ISBus.
………
F00 SPEED REG / Speed ref
F00.10 - Dig speed ref 1
It is possible to configure (see Pick List 09):
000-DigSpd Ref 1 it states the reference value
F00 SPEED REG / Speed ref
F00.30 - Speed ref 1 mon
It is possible to monitor:
Speed ref 1 mon it states the reference value