2. To change the engineer entry code, press the ▼
(down) key to highlight Engineer Program then
press the ↵ (Edit) key. The LCD will display the
Edit Pin screen as shown. Enter a new pin
number using the drink selection keypad and
press the ↵ (Edit) key.
Note: This security number is not displayed. Be sure to record the new pin code
and keep it in a safe place.
3. Highlight Operators Program and follow the above procedure to change the
operator code. Ensure that all operators who use the machine are issued with
the new code.
4.9 Timed Events Menu
1. Time of Day Events: From this menu the engineer can set up inhibited vend
periods, free vend periods and discounted vend periods.
The following example describes how the engineer can program the machine to free
vend specific drink selections between 10.30 am and 2:30 pm on week days.
1. From the Main Menu press the
▼ (down) key
until Timed Events is highlighted then press the
↵ (Edit) key twice to access the Time of Day
menu screen. The LCD will display the screen as
shown.
Note: Although event 1 is shown as Inhibit, it is possible for the engineer to set
event 1 as the first Free Vend (or Discounted Vend) period.
2. Press the ↵ (Edit) key to access the menu. The
LCD will display the screen as shown. By default
the current State is set to Off as indicated by the
status line at the bottom of the screen.
3. Press the ↵ (Edit) key to access the State sub
menu. Using the
▼ (down) key, set the state to
On (indicated by the filled radio button). Press
the ↵ (Edit) key to return to the Event 1 screen.
Verify that the status line confirms the State is set
to On.
49
Technical Manual