All measurements and coordinate computations are referenced to the set station
coordinates.
The station coordinates that are set must include:
•
at least grid coordinates (E, N), and
•
the station height, if necessary.
In Q-Survey, the coordinates can be entered manually only.
1. In Q-Survey, press F4 twice to display the third
softkey level. Press the softkey Station (F1).
2. The screen "Input STA" is displayed.
•
Enter the name of the station, the instrument
height and the coordinates.
•
To save the station data and return to Q-Sur-
vey, press OK (F4).
•
To cancel and return to Q-Survey, press ESC.
Set the horizontal angle to zero
1. In Q-Survey, press F4 twice to display the third
softkey level. Press the softkey Zero (F2).
2. The screen "Set HA=0?" is displayed.
•
To set the horizontal angle to zero and return
to Q-Survey, press Yes (F4).
•
To cancel and return to Q-Survey, press No
(F1).
Set the horizontal angle to any desired value
☞
You can either enter the desired value manually or use the current orientation of the
instrument. Aim the instrument at the desired target point to set the orientation.
1. In Q-Survey, press F4 twice to display the third
softkey level. Press the softkey SetHA (F3).
Set the station coordi-
nates (Q-Survey)
Set the station orientation
(Q-Survey)
28 Operation