2.1.12. SMPTE Version
Description:
The clock will be used to read and display SMPTE or EBU time code at standard scrolling speed.
Performances :
Automatic adjustment to SMPTE or EBU format.
Automatic selection of frame rate at 24, 25, 29.97 or 30 images per second.
Maximal error tolerance of frame rate of received code: +/-10%.
Electrical specifications of received SMPTE/EBU code:
Input level: Mini +/- 0,7 Volts - Maxi +/- 12 Volts
Input impedance: 12 Kohms
Description of SMPTE message with date information: Refer to table next page.