28
MDE-LEDI-1099V4.0
Specific version with indicator for absence of sync:
Same protocol as the table above, but when the clock has not received the right sync code yet, or when
the sync signal disappears during more than 24hours, the field “DAY” indicates 3 symbols « ### ».
The 2nd part of 12 extra octets is not generated in this version.
2.2.3. Date / time alternation option (only LEDI
®
)
The clock can be set to display time and date alternating.
The display period for time or date is configurable from 0 to 15 seconds (0 to do not display)
Date/ time change is also available on double face (LEDI REVERSO)
2.2.4. Temperature Option
The clock can be set to display time and date alternating.
The display period for time or date is configurable from 0 to 15 seconds (0 to do not display)
Offset setting available for temperature
Measurement range -15°C ► +65°C accuracy +/-0.4°C
Air and water temperature available by probe
The clock can display several zones of temperature through a wire probe or/and wireless (only
LEDI POOL)
Wired version :
Temperature through probe PT1000 delivered with 4m cable.
En version sans fil :
SNMP sensor station (Ethernet and Wi-Fi):
Up to 3 1-Wire Temperature or Humidity probes (1m, 3m, 5m)
230V and PoE power supply
Potentially unlimited distance between the clocks and the station due to the network connection