Product version as x.x.x.x
Synchronization message as presented on the homepage
("Synchronization Status:" field)
In recovery, returns the UTC time and date of the product.
In configuration:
- If the current mode is NTP, a "Read-Only" error is returned.
- - If the mode is Autonomous, then the UTC date is updated.
Type of NTP mode or autonomous mode.
Last correction made on the product time compared to the received
time
Product reset.
In reading mode, the information is always 0.
Retrieves the battery status. Always returns 0, which is equivalent to
"battery high".
Retrieves the Wi-Fi power in dBm if the product is in Wi-Fi. If the
product is in Ethernet, a string like "No Wi-Fi configured" will be
returned.
Recovers the current state of the clock display.
Display time, in seconds, between the date and the time on the Hours-
Minutes-Seconds display
Display time, in seconds, between the temperature and the time on
the Hours-Minutes-Seconds display
Temperature value read by the product, via the temperature sensor.
If the temperature option is not present, the returned value will be "--
.-"
Active/inactive status of buttons
If the buttons option is present, then this command can block or not
the use of the buttons to avoid unwanted manipulations.
Current mode of the NTP connection:
- Client/server
- Broadcast
- - Other
Status of the automatic detection mode of NTP servers or the auto-
configuration mode
- Synchronization status of the current NTP client
- Best candidate for sharing time information
- Current server selected for synchronization by the NTP client
ntpInputActiveServ
erAddress
IPv4 address of the selected NTP server
Number of requests sent for each 10ms interval
Number of NTP servers that can be used
Identifies each server with a particular index 0,1,2 or 3
IPv4 address of the server corresponding to the selected index
Status (enable/disable) of the server corresponding to the selected
index