FC4500-UM-251-9370 117
7 ELECTRICAL SECTION
(25) Measure the offset of X and Y, and then input the offset value for the X and the Y direction.
Press the [F2] key to select the X value at the above menu.
Press the [F4] key to select the Y value at the above menu.
The value can be changed by using up or down arrow keys.
Input the minus value when the drawn cross mark is shifted to the plus direction.
And you can input the factory recorded values for the Y of registration mark sensor at this times.
(26) Press the [ENTER] key after adjustment values were input.
(27) The following menu is displayed.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
X ADJ.SENS POS Y
+X +Y
(28) Press the [Next Page] key to display the following menu.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
ARMS ADJUST
PRESS ENTER KEY!!
(29) You don’t need to perform the following steps if you want to continue to the next adjustment.
(30) When this adjustment was nished correctly, turn off the power.
(31) Set the DIP switch to the normal settings.