FC4500-UM-251-9370 129
7 ELECTRICAL SECTION
(12) Press the [F4] (400x500) key to select the 400x500 size.
(13) Press the [ENTER] key to display the following menu.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
ORIGINAL CLEAR
ADJ.DRAW INPUT
Each keys are corresponding to the following operations at this menu.
F1: Plotter draws the adjustment pattern without adjustment.
F2: Plotter draws the adjustment pattern with adjustment.
F3: The distance adjustment values are cleared.
F4: The adjustment value input menu is displayed.
(14) Press the [F4] key to input the recorded values if the main board was replaced only.
Skip to Step (20) to input the recorded values.
(15) Press the [F2] key to draw the adjusted pattern to conrm the distance accuracy.
The plotter draws a pattern as shown in the picture below.
Y=400mm
X=500mm
(16) Measure the distance of X and Y that have 500 mm and 400 mm.
You don’t need to adjust the distance accuracy if the measured distance has 500 mm x 400 mm.
(17) Press the [F1] key to draw the pattern without adjustment if it needs to adjust.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
ORIGINAL CLEAR
ADJ.DRAW INPUT
(18) Measure the distance of X and Y and L (diagonal lines).
Y