FC4500-UM-251-9370 130
7 ELECTRICAL SECTION
(19) Calculate the adjustment values by the following calculation formula.
X adjustment value = (500 - (Measured distance of X)) x 100
Y adjustment value = (400 - (Measured distance of Y)) x 100
L adjustment value = Measured distance of L
For example:
X measured distance is 500.1mm, Y measured distance is 399.8 mm
X adjustment value:
-10 = (500-500.1) x 100
Y adjustment value:
+20 = (400-399.8) X 100
(20) Press the [F4] key to display the adjustment values input menu from the following menu.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
ORIGINAL CLEAR
ADJ.DRAW INPUT
(21) The following menu is displayed. Then input the adjustment values for the X and the Y.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
DIST. ADJ.(0.01mm)
X =+10 Y =-10
Each keys are corresponding to the following operations.
F1 Key: Increasing the X adjustment value by 0.01 mm step
F2 Key: Decreasing the X adjustment value by 0.01 mm step
F3 Key: Increasing the Y adjustment value by 0.01 mm step
F4 Key: Decreasing the Y adjustment value by 0.01 mm step
(22) Press the [Enter] key after the X and the Y adjustment values were input.
The following menu is displayed. Then input the adjustment values for the L.
FORCE
SPEED
OFFSET
QUALITY
F1 F3
F4
F2
+0.1 X-Y LENG -0.1
+0.01 L=640.31 -0.01
Each keys are corresponding to the following operations.
F1 Key: Increasing the L adjustment value by 0.1 mm step
F2 Key: Increasing the L adjustment value by 0.01 mm step
F3 Key: Decreasing the L adjustment value by 0.1 mm step
F4 Key: Decreasing the L adjustment value by 0.01 mm step