EasyManua.ls Logo

GRAPHTEC FC 4500 Series - 6.23 Y Belt Tension Adjustment

GRAPHTEC FC 4500 Series
190 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FC4500-UM-251-9370 36
6 REPLACEMENT PROCEDURES
How to install the Registration Mark Sensor
(1) Reattach the Registration Mark Sensor in the reverse order in which it was detached.
(2) Adjust the Registration Mark Sensor Bracket height when the two M3L6 binding head screws are
tighten.
FC4500-50 / FC4500-60
Adjust the Registration Mark Sensor Bracket height to the 3.75 mm from the Writing Panel as shown
in the picture below.
M3L6 binding head screw
Registration mark sensor bracket
3.75 mm
FC4510-60
Adjust the Registration Mark Sensor Bracket height to the 5 mm from the Writing Panel as shown in
the picture below.
5 mm
Registration mark sensor bracket
M3L6 binding head screw
(3) Perform the Registration Mark Sensor Level Adjustment when the Registration Mark Sensor was
replaced, or when the Registration Mark Sensor Bracket was reinstalled (See section 7.7.).
(4) Perform the Registration Mark Sensor Position Adjustment when the Registration Mark Sensor was
replaced, or when the Registration Mark Sensor Bracket was reinstalled (See section 7.8.)(See
section 7.9.).

Table of Contents