12-10
12.5
Communication Timeout
When the communication is lost during connecting to the data link server, the connection will be canceled after a
certain period of time has elapsed. You can set the time until it is canceled.
Operation
1
Press the [PAUSE/MENU] key.
MENU screen is displayed.
2
Press the POSITION (
) key (LINK).
DATA LINK screen (1/2) is displayed.
3
Press the POSITION ( ) key.
DATA LINK screen (2/2) is displayed.
4
Press the [2] key (COMMUNICATION TIME OUT ).
COMMUNICATION TIME OUT screen is displayed.
Supplement
You can set the range between 5 and 15 sec.
5
Press the POSITION ( ) key and increase or decrease the
setting value.